EpiQuik Histone H3 Citrullination ELISA Kit (Colorimetric)

Share:

For ELISA-like measurement of total citrullinated histone H3 (at arginines R2, R8, R17)

Write a Review
Schematic procedure of Histone H3 Citrullination ELISA kit (Colorimetric)
Histone extracts were prepared from HL-60 cells using the EpiQuik™ Total Histone Extraction Kit and the amount of H3cit was measured using the EpiQuik™ Histone H3 Citrullination ELISA Kit (Colorimetric).
Illustrated standard curve generated
Demonstration of high sensitivity and specificity of H3cit detection achieved by EpiQuik™ Histone H3 Citrullination ELISA Kit (Colorimetric). H3cit, unmodified H3 and methylated H3 at arginine site 2, 8 and 17, respectively were added into the assay wells at the different concentrations and then measured with the EpiQuik™ Histone H3 Citrullination ELISA Kit (Colorimetric).
Input Type: Histone Extracts
Research Area: Histone Citrullination
Target Application: Amount Quantitation
Vessel Format: 96-Well Plate
100% Guarantee: 6 months
Catalog No.SizePriceQty
P-3095-4848 assays $349.00 
P-3095-9696 assays $596.00 
Availability: Usually Ships In 1-2 Days 
Product Overview

The EpiQuik™ Histone H3 Citrullination ELISA Kit (Colorimetric) is a complete set of optimized buffers and reagents for specifically measuring global histone H3 citrullination from a broad range of species such as mammals, fungi, and bacteria, in a variety of forms including cultured cells and fresh tissues. Histone extracts can be prepared by using your own successful method. For your convenience and the best results, EpiGentek offers a histone extraction kit optimized for use with this kit. Histone extracts can be used immediately or stored at –80°C for future use. This kit has the following advantages:

  • Quick and efficient procedure, which can be finished within 3.5 hours.
  • High sensitivity and specificity. The detection limit is as low as 0.1 ng/well with dynamic range of  0.5-10 ng/well within the indicated amount range of the histone extracts. Only recognizes H3cit with no cross-reactivity with unmodified H3 or other modifications at the same arginine site.
  • The control is conveniently included for the quantification of H3cit.
  • Strip microplate format makes the assay flexible: manual or high throughput.
  • Simple, reliable, and consistent assay conditions.

Background Information
Arginine histone citrullination is one of the many important epigenetic marks, and is essential for the regulation of epigenetic chromatin remodeling and immune cell’s extracellular trap processes. Citrullinated arginine of histone H3 (Arg2, 8, 17) regulates gene expression and is mainly catalyzed by peptidylarginine deiminase 4 (PAD4). Furthermore, citrullination of histones, in particular histone H3, was revealed as a convergence point for diverse inflammatory signals that trigger the neutrophil response to infections. It was reported that citrullinated histone H3 could be a potential serum biomarker for the early diagnosis of septic shock. More immunological diseases such as multiple sclerosis and rheumatoid arthritis seem to be also associated with change of histone H3 citrullination. The global histone H3 citrullination can be changed by inhibition or activation of PADs. Therefore, quantitative detection of global histone H3 citrullination would provide useful information for better understanding epigenetic regulation of gene activation and silencing, as well as for developing PAD-targeted drugs. 

Principle & Procedure
This kit is designed for measuring global H3cit. In an assay with this kit, the histone proteins are stably spotted on the strip wells. The citrulline H3 can be recognized with a high-affinity antibody and detected with a detection antibody, followed by a color development reagent. The ratio of H3cit is proportional to the intensity of absorbance. The absolute amount of H3cit can be quantitated by comparing to the standard control.

Starting Materials
Input materials should be histone extracts. The amount of histone extracts for each assay can be 50 ng to 200 ng with an optimal amount of 100 ng.

Product Components

WB (10X Wash Buffer)
BB (Blocking Buffer)
DS (Developer Solution)
SS (Stop Solution)
HCB (Histone Coating Buffer)
8-Well Assay Strips (With Frame)
Control Strips (With Frame)#
Adhesive Covering Film
CAb (Capture Antibody, 1000X)*
DAb (Detection Antibody, 1000X)*
H3cit Control ( 50 µg/ml)

*Spin the solution down to the bottom prior to use.
#Control Strips are green trimmed for distinguishing from 8-well Assay Strips (for samples). 

The Control Strips are only for control use and should not be used for sample assay. 

 

User Guide & MSDS

[User Guide]*
*Always use the actual User Guide that shipped with your product. Is the above file locked? You can also request user guides by emailing info@epigentek.com along with your contact information and institution name.

Replace Your Santa Cruz Abs
Related Products

Researchers Also Purchased
EpiQuik Total Histone Extraction Kit
EpiQuik Total Histone Extraction Kit
EpiQuik Total Histone H4 Quantification Kit (Fluorometric)
EpiQuik Total Histone H4 Quantification Kit (Fluorometric)
EpiQuik Total Histone H3 Quantification Kit (Fluorometric)
EpiQuik Total Histone H3 Quantification Kit (Fluorometric)
EpiQuik Total Histone H4 Acetylation Detection Fast Kit (Fluorometric)
EpiQuik Total Histone H4 Acetylation Detection Fast Kit (Fluorometric)
Epigentek is an epigenetics company that specializes in epigenetic kits, antibodies, reagents, and services for epigenetic research in DNA methylation, histone modification, and chromatin studies. Terms & Conditions | Privacy Policy | Site Map
Copyright © 2017 Epigentek Group Inc. All rights reserved.